![]() If HPMC is used, a standby IOL should be ready at the time of implantation. These small peripheral cracks have no ill-effects on the visual outcome and stability of the IOL in the short term. These factors could induce stress at the optic-haptic-junction leading to the crack. This may lead to movement of optic followed by movement of trailing haptic after a time lag, due to inherent design of the injector. 6 With HPMC, the force required to dislodge optic and haptic from the cartridge at initiation of injection is higher. Hydroxylpropylemethyl cellulose has lower pseudo-plasticity 6 than other viscoelastics, hence it is more difficult to begin and maintain injection through the cannula. In our case, proper technique for injection was followed, with use of HPMC. Santa Ana, CA-Advanced Medical Optics Inc.'s (AMO) Silver Series Unfolder can be used successfully with the Tecnis and CeeOn IOLs, which the company recently acquired from Pfizer Ophthalmics. This was the first complication of IOL damage. ![]() Though manufacturers instruct to avoid use of Healon TM with Unfolder TM, its use without any lens damage has been reported. We have been using HPMC for insertion of Phacoflex-II using Unfolder TM for the past three years without any damage to the IOL. Among silicone IOLs this complication has only been reported once with Clariflex but has never been reported with Phacoflex-II. There are reports 1, 2, 3 of IOL damage during implantation. 19.99 This product was viewed 63 times within last week Real time 6 visitor right now Order in the next 00:46:18 to get it by Friday, JAvailability: In stock (2) Collection: Medical Supplies & Disposables Weight: 14. The UNFOLDER Silver handpiece with the One Series cartridge implantation system is used to fold and assist in inserting TECNIS 1-Piece intraocular lenses into the capsular bag. Intraoperative photograph showing cracked Phacoflex-II IOL in the capsular bagĪfter six weeks, the IOL remained stable and well centered, without compromising BCVA. On the first post surgical day, the patient had BCVA of 20/20. In spite of the crack, the IOL was well centered in the bag. The IOL optic had opened and it was impossible to withdraw. Leading haptic was implanted successfully, while crack was noted at the trailing haptic-optic junction. Phacoflex-II was loaded into Unfolder TM using HPMC according to the manufacturer′s instructions. Phacoemulsification was performed in the right eye. ![]() 4Ī 56-year-old male presented with bilateral immature senile cataract with best corrected visual acuity (BCVA) of 20/80 in right eye and 20/40 in left eye. 2 We report cracking of Phacoflex-II during insertion, using hydroxylpropylemethyl cellulose (HPMC) with Unfolder TM system. Damage to acrylic 1, 2 and Clariflex 3 IOLs during implantation has been reported most of them do not affect visual outcome but may need explantation. Silicone and acrylic intraocular lenses (IOLs) are commonly used after phacoemulsification.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |